| CODE | NEAREST SAE (B&S) (AWG) | CONDUCTOR NO/DIA (mm) | NOMINAL AREA (mm²) | AMP RATING | INSULATION THICKNESS (mm) | ELECTRICAL RESISTANCE @ 20°C (ohm/km) | NOMINAL O.D. (mm) | MASS (kg/100m) | 
| HVT1702 | 24 | 7/0.2 | 0.22 | 1.4 | 0.3 | 89.0 | 1.2 | 0.32 | 
| HVT17025 | 22 | 7/0.25 | 0.34 | 2 | 0.38 | 57.4 | 1.6 | 0.53 | 
| HVT110025 | 20 | 10/0.25 | 0.5 | 3 | 0.38 | 38.0 | 1.8 | 0.71 | 
(ii) Not Suitable For Connection To Mains Power Supply
(iii) Maximum operating temperature: 75°C in normal use OR 105°C where not subject to, or is protected from, mechanical damage (refer AS/NZS 3008.1.1:2009 Table 1 Clause 3).
 
				 
															