Single Core Hook-up (Connecting Wires)

Single Core Hook-up (Connecting Wires)

Applications: Extra Low Voltage internal equipment wiring
Conductor: Tinned Copper Wire to AS/NZS 1125
Insulation: RoHS Compliant V-90HT (105C) PVC to AS/NZS 3808
Colour: Black, Blue, Brown, Green, Grey, Orange, Pink, Red, Violet, White, Yellow
Packs: 100, 500, 1000 metres - other packs by request

CODENEAREST SAE (B&S) (AWG)CONDUCTOR NO/DIA (mm)NOMINAL AREA (mm²)AMP RATINGINSULATION THICKNESS (mm)ELECTRICAL RESISTANCE @ 20°C (ohm/km)NOMINAL O.D. (mm)MASS (kg/100m)
HVT1702247/0.20.221.40.389.01.20.32
HVT17025227/0.250.3420.3857.41.60.53
HVT1100252010/0.250.530.3838.01.80.71
(i) Maximum Working Voltage: 42V RMS
(ii) Not Suitable For Connection To Mains Power Supply
(iii) Maximum operating temperature: 75°C in normal use OR 105°C where not subject to, or is protected from, mechanical damage (refer AS/NZS 3008.1.1:2009 Table 1 Clause 3).