CODE | NEAREST B&S | CONDUCTOR NO/DIA (mm) | NOMINAL AREA (mm²) | INSULATION THICKNESS (mm) | * AMP RATING JASO D609 @30°C | ELECTRICAL RESISTANCE @ 20°C (ohm/km) | NOMINAL O.D. (mm) | MASS (kg/100m) |
MBS111203 | 8 | 96/0.32 | 8 | 0.9 | 74 | 2.50 | 5.75 | 9.2 |
MBS132002 | 320/0.2 | 10 | 1.1 | 84 | 1.95 | 6.35 | 11.4 | |
MBS119203 | 6 | 168/0.32 | 13.5 | 1.1 | 103 | 1.42 | 7.2 | 15.6 |
MBS122403 | 224/0.3 | 16 | 1.2 | 110 | 1.24 | 7.8 | 17.7 | |
MBS128703 | 4 | 252/0.32 | 20.26 | 1.1 | 135 | 0.91 | 8.3 | 22.4 |
MBS136403 | 3 | 329/0.32 | 25.7 | 1.6 | 168 | 0.79 | 10.2 | 29.2 |
MBS145503 | 2 | 399/0.32 | 32 | 1.7 | 188 | 0.62 | 10.3 | 36.5 |
MBS149403 | 1 | 492/0.32 | 35 | 1.7 | 210 | 0.56 | 11.4 | 38.4 |
MBS172803 | 0 | 708/0.3 | 50 | 1.7 | 246 | 0.39 | 13.2 | 54.5 |
Derating Factors for Bundling of Single Core Cables | ||||||||
No of Cables | 1 | 2 | 3 | 4 | 5 | 6 to 7 | 8 to 10 | 11 to 12 |
Factor | 1 | 0.8 | 0.7 | 0.6 | 0.55 | 0.5 | 0.45 | 0.4 |
Derating Factors for Ambient Temperatures °C | |||||
Temperature | 30 | 40 | 50 | 60 | 70 |
Factor | 1.00 | 0.90 | 0.76 | 0.60 | 0.45 |