Garden Lighting – Figure 8

Garden Lighting – Figure 8

Applications: Garden Lighting Systems
Conductor: OXYGEN FREE Plain Copper Wire to AS/NZS 1125
Insulation: RoHS Compliant UV Resistant V90HT P.V.C. to AS/NZS 3808
Colour: Black
Packs: 50, 100 metres – other packs by request

CODENO. OF CORESCONDUCTOR NO/DIA (mm)NOMINAL AREA
(mm²)
INSULATION THICKNESS
(mm)
ELECTRICAL RESISTANCE @ 20°C (ohm/km)NOMINAL O.D.
(mm)
MASS
(kg/100m)
POLARITY IDENTIFICATION
(No. of Raised Ribs on 1 leg)
FAIRY LIGHTS
LFD23202232/0.21.00.626.72.6 x 5.73.10
LFD230025230/0.251.51.113.74.0 x 8.36.02
LFD24802248/0.21.51.113.74.1 x 8.46.32
GARDEN LIGHTS
LFD2105022105/0.23.30.85.64.2 x 8.97.84
LFD25603256/0.341.04.954.7 x 9.510.81
LFD2127022127/0.241.04.634.7 x 9.510.81
LFD2192022192/0.261.03.15.5 x 11.514.54
LFD2322022322/0.2100.661.836.0 x 12.522.04
NOTE: (i) Not Suitable For Connection To Mains Power Supply

FIGURE 8 GARDEN LIGHTING – RECOMMENDED RUN LENGTH

12 VOLTS LOADMAXIMUM DISTANCE IN METRES
AmpsWatts1mm²1.5mm²2.9mm²3.3mm²4mm²6mm²10mm²
1.672017265057.369.5104173
3.33408.5132528.634.75287
4.1750710.42022.927.84169
5.00605.68.61619.123.13458
5.837057.41416.319.82950
6.67804.36.51214.317.32643
7.50903.95.71112.715.42338
8.331003.45.21011.713.92034
10.001202.84.389.511.51729
11.671403.778.19.91524
13.331603.267.18.61321
15.001802.85.56.37.71119
16.6720055.76.91017
NOTE: Maximum One (1) volt drop allowed in applications

Tyree Cable Australia Pty Ltd

Choose Tyree Cable Australia for electrical solutions that power progress, innovation, and reliability.

Phone:

(03) 8791 0300

Email:

enquiries@tycab.com.au

Address:

15 Tatterson Road, Dandenong South, Vic, 3175

Address:

269 Frankston - Dandenong Rd, Dandenong Sth, Vic, 3175

Enquiry Form