Air Conditioning Cable
CODE NO. OF CORES NOMINA AREA (mm²) CONDUCTOR NO/DIA (mm) INSULATION THICKNESS (mm) SHEATH THICKNESS (mm) ELECTRICAL RESISTANCE @ 20°C (ohm/km) NOMINALO.D. (mm) BAC4705 2C+E 1.5 7/0.5 0.6 0.9 13.6 4.6 x 12.7 BAC47067 2C+E 2.5 7/0.67 0.7 1.0 7.4 5.5 x 15.7 Maximum operating temperature: 75°C in normal Use OR 90°C where not subject […]
Non-migratory Thermoplastic Sheathed (TPS) Flat
CODE NO. OF CORES NOMINAL AREA (mm²) CONDUCTOR NO/DIA (mm) INSULATION THICKNESS (mm) SHEATH THICKNESS (mm) NOMINAl O.D. (mm) MASS (kg/100m) BED3705 2C+E 1.5 7/0.5 0.6 0.9 4.6 x 9.9 8.9 BED37067 2C+E 2.5 7/0.67 0.7 1.0 5.5 x 12.2 14 CURRENT RATING ELECTRICAL CHARACTERISTICS Unenclosed In Air Completely surrounded by thermal insulation Unenclosed partially […]
Single Core Hook-up (Connecting Wires)
CODE NEAREST SAE (B&S) (AWG) CONDUCTOR NO/DIA (mm) NOMINAL AREA (mm²) AMP RATING INSULATION THICKNESS (mm) ELECTRICAL RESISTANCE @ 20°C (ohm/km) NOMINAL O.D. (mm) MASS (kg/100m) HVT1702 24 7/0.2 0.22 1.4 0.3 89.0 1.2 0.32 HVT17025 22 7/0.25 0.34 2 0.38 57.4 1.6 0.53 HVT110025 20 10/0.25 0.5 3 0.38 38.0 1.8 0.71 (i) Maximum […]
Multi-core Composite Trailer
CODE NO. OF CORES CONDUCTOR NO/DIA (mm) NOMINAL AREA (mm²) **AMP RATING @ 30°C INSULATION THICKNESS (mm) SHEATH THICKNESS (mm) ELECTRICAL RESISTANCE @ 20°C (ohm/km) NOMINAL O.D. (mm) MASS (kg/100m) ATC24/515 2 X 56/0.3 4.0 37 0.6 1.0 4.95 12.8 23.2 3 X 30/0.25 1.5 18 0.4 13.3 1 Pair […]
Twin Twist Explosive Cable
CODE NEAREST SAE (B&S) (AWG) NO. OF CORES CONDUCTOR NO/DIA (mm) NOMINAL AREA (mm²) AMP RATING INSULATION THICKNESS (mm) ELECTRICAL RESISTANCE @ 20°C (ohm/km) NOMINAL O.D. (mm) MASS (kg/100m) EXR21061 22 ½ 2 1/0.61 0.29 1.8 0.4 64.0 1.4 0.9 EXR21071 21 2 1/0.71 0.40 2.4 0.3 46.0 1.3 1.03 (i) Extra low voltage(ii) Not Suitable […]
Twin Sheath Two Core Flat
CODE NO. OF CORES CONDUCTOR NO/DIA (mm) NOMINAL AREA (mm²) INSULATION THICKNESS (mm) SHEATH THICKNESS (mm) ELECTRICAL RESISTANCE @ 20°C (ohm/km) NOMINAL O.D. (mm) MASS (kg/100m) EWC250025 2 50/0.25 2.5 0.8 1.6 7.6 7.3 x 11.0 14.6 EWC25603 2 56/0.3 4.0 0.8 1.1 4.95 6.4 x 10.5 EWC27104 2 7/1.04 6.0 0.8 1.1 3.08 7.0 […]
Twin Sheath Two Core Flat
● Excellent durability and flexibility
● Simple to strip and easy to install
● Made for all Australian climates and conditions
● Designed as a DC power cable and to withstand the high impact of DC current
● Enhanced electrical safety and environment protection (Double Insulated)
Flat Fire Alarm 450/750 VOLT
Code Cores ConductorNo. / Dia(mm) NominalArea(mm²) *AMPRating InsulationThickness(mm) SheathThickness(mm) ElectricalResistanceat 20°C(ohm/km) NominalO.D.(mm) Mass(kg/100m) BWA2704 2 7/0.4 1 10 0.6 0.9 21.2 4.2×6.7 4.4 BWA2705 2 7/0.5 1.5 15 0.6 0.9 13.6 4.5×7.2 5.4 * AMP Ratings are to AS3008. Unenclosed-Spaced at 40°C. Refer to AS3008 for derating factors.
Flat Fire Alarm
● V90 PVC insulation and sheath
● Flat Red and White cores
● Best used in evacuation systems, smoke detectors and alarms
Screened Twisted Fire Alarm
● V90 PVC insulation and sheath
● Includes an aluminium / polyethylene screen
● Tinned Copper Drain Wire
● Resistant to signal interference